Manual Vacuum Aspirator Kit (MVA) Kit is containing of:
Autoclavable Double Valve MVA (Manual Vacuum Aspirator) Syringe with a capacity of 60ml.
All accessories including silicone oil.
Karman Cannula sizes 4, 5, 6, 7, 8, 9, 10 & 12, one each
Detailed information of Double Valve MVA Syringe:
Components of Manual Vacuum Aspirator Double Pinch Valve Syringe, 60ml
|
Detailed information
|
Plunger |
A component that inserts into the cylinder and when pulled creates the vacuum. Material: Polypropylene.
|
Cylinder |
Main holding vessel of the aspirator. Material: Polypropylene
|
Valve Body |
Case to enclose the valve mechanism. Material: Polypropylene.
|
Collar Stop
|
Clip on top of the cylinder, which prevents the plunger from being removed from the cylinder. Material: Polypropylene
|
O-ring |
A rubber ring(Black) is inserted onto the end of the plunger making the plunger slide into The cylinder and creating a vacuum.
Material: Buna-Nitrile rubber(Synthetic Rubber) |
Buttons |
Knobs when pressed close off the liner that creates a vacuum when the plunger is pulled.
Material: Polypropylene |
Liner Clamp |
A mechanism that closes off the liner, which creates a vacuum in the cylinder when the plunger is pulled.
Material: Polypropylene |
Liner |
The soft tubular part clamps off to create the vacuum.
Material: Poly-dimethylsiloxane (Silicone Rubber) |
Valve Cap |
The component at the end of the valve body. Helps to hold the cannulae or adapter in place.
Material: Polypropylene |
Polypropylene Barrel Capacity 60 ML.
Suction capacity: Provides above 24 inches of hg ( mercury)/609.6 mm of hg( mercury) Vacuum. Maintain this vacuum for more than Sixty minutes.
Compatible with fixed adapter Karman cannulae sizes 4-12 mm.
The valve liner is removable by opening a hinged valve body. Double locking valve allowing the creation of vacuum prior to the procedure. The valve liner provides a clear fluid path.
The aspirator features a secure stopping mechanism for the plunger when pulled. The collar stop is able to be displaced or removed for removal of plunger. A cylinder is marked in 10cc increments to measure evacuated uterine contents.
With an ergonomic handle.
Aspirators is able to be boiled and steam sterilized (autoclaved) at 250°F or 121°C. Can be sterilized with STERRAD 100s and can be processed by standard cold methods.
Shelf life: 5 years from the month of manufacture.
Suitable to be reused a minimum of 25 - 50 times under normal use and maintenance.
ALSO AVAILABLE SAME SET WITH SINGLE-VALVE MVA SYRINGE